Brivis Buffalo Troubleshooting: Common Problems and What They Mean
The Brivis Buffalo is one of the most popular ducted gas heaters in Melbourne. Tens of thousands of these units sit in subfloors, roofs, and beside homes across the metro area. Some have been running for 20 or even 30 years without missing a beat.
But when something goes wrong on a cold morning, it helps to understand what your heater is telling you. This guide covers the most common Brivis Buffalo problems Melbourne homeowners run into, what the LED flash codes mean, and when to call a professional for Brivis heater servicing and repairs.
Table of Contents
The Two Different Ignition Types
The Brivis Buffalo is an external or semi-external gas ducted heater. It draws return air from inside your home, heats it through a gas-fired heat exchanger, and pushes warm air back through your ductwork.
Older models like the Buffalo 85 and Buffalo 20 use a standing pilot light and thermocouple. Newer BX3 and BX5 models use electronic spark ignition and a flame sensor rod. Both generations rely on a control board (PCB) that monitors safety circuits and manages the ignition sequence.
Understanding which generation you have makes a big difference when troubleshooting. If your unit has a small flame burning constantly near the burners, you have a standing pilot model. If you hear clicking or sparking sounds when the heater starts, you have an electronic ignition model.
The Most Common Brivis Buffalo Problems
Here are the issues we encouter the most with Brivis Buffalo ducted gas heaters:
1. Heater Blowing Cold Air
This is probably the most frequently reported Brivis Buffalo complaint. The fan runs, air comes through your vents, but there is no warmth.
A few things can cause this. On older models, the pilot light may have gone out. On electronic ignition models, the igniter may have failed or the flame sensor could be dirty. In some cases, the fan limit switch is stuck in the open position, which keeps the fan running without allowing the gas to fire.
One homeowner described their Buffalo 85 running the fan and clicking as if trying to ignite, only for the burners to shut off after 10 seconds and the EPRL error light to come on. In that case, cleaning the flame sensor rod resolved the issue.
What to check first: Make sure your thermostat is set to heat (not fan only or cool). Confirm the gas supply is on. If you have a pilot light model, check whether the pilot is still lit.
2. Heater Won’t Start at All
Your thermostat is set, the power is on, but the heater does nothing. No fan, no flame, no clicking.
On older Buffalo models, the most common cause is a failed thermocouple. The thermocouple is a small sensor that sits in the pilot flame. It tells the gas valve that the pilot is lit and it is safe to open the main gas supply. When the thermocouple wears out, the gas valve stays shut.
On BX3 and BX5 models, a non-starting heater often points to a faulty control board (PCB). The control board is the single most common part to fail on newer Buffalos, particularly on units older than 8 to 10 years. Heat exposure inside the unit gradually dries out capacitors and degrades solder joints on the board.
What to check first: Try a power reset. Turn the heater off at the wall for 30 seconds, then turn it back on. Repeat this three times within 60 seconds. This will reset the system. If this doesn’t work, call our team on 1800 296 885 to book a Brivis service.
3. Heater Starts Then Cuts Out
The heater fires up, runs for 5 to 15 minutes, then shuts down. You might get a couple of good heating cycles before it refuses to restart.
This pattern almost always points to an airflow restriction causing the unit to overheat. The safety switch trips, the heater shuts down, and you see a 1-flash or 7-flash error code on the control board.
This problem is often related to to collapsed return air ducts (especially flexible duct that has sagged over time), blocked filters, closed or obstructed vents, and even disconnected ductwork at junction points.
What to check first: Check your return air grille and filter. A clogged filter is the easiest fix. Then check any accessible ductwork for signs of sagging, crushing, or disconnection.
4. Pilot Light Won’t Stay Lit
This one is almost exclusive to older Buffalo models (Buffalo 52, 85, and 20) with standing pilot lights.
If the pilot lights when you hold the button down but goes out when you release it, the thermocouple is the likely culprit. The thermocouple needs about 30 seconds of flame contact to generate enough electrical current to hold the gas valve open. If it has worn out or is coated in soot, it cannot produce enough current.
What to check first: Relight the pilot following the instructions on the unit’s label. Hold the pilot button down for a full 60 seconds before releasing. If the flame still goes out, the thermocouple likely needs replacing. This is a common and relatively affordable repair.
5. Strange Noises at Startup
Clicking, banging, or small “popping” sounds when the heater starts can be alarming, but they are often related to delayed ignition. Dust and debris accumulate in the burner venturis over summer, and when gas finally ignites after a slight delay, you get a small bang.
Regular pre-season servicing clears this buildup and keeps ignition smooth.
6. Insects and Pests Inside the Unit
This is one that surprises many homeowners. Ants, spiders, and other insects can nest inside the heater over summer. External Buffalo units are particularly prone to this because they sit outside year-round. A pre-winter inspection can catch pest issues before they cause a breakdown.
7. Thermostat Problems
A faulty or misconfigured thermostat can make it look like your Brivis Buffalo has a serious problem when the unit itself is fine. Common thermostat issues include flat batteries (most Brivis wall controllers run on AA or AAA batteries), a thermostat set to “cool” or “fan only” instead of “heat”, and loose wiring connections at the thermostat or at the heater’s terminal block.
On older Buffalo models, some homeowners find that the thermostat sends the call for heat but the heater does not respond. A simple test for this is to bridge the W and R terminals at the heater itself. If the heater fires up with the terminals bridged, the problem is in the thermostat or the wiring between the thermostat and the unit, rather than the heater itself.
Newer BX5 and StarPro models that use the Brivis Networker controller can display error codes directly on the wall unit screen, which makes diagnosis easier. If your Networker screen shows a spanner icon, it means the heater has locked out and needs a reset.
What to check first: Replace the thermostat batteries. Check that the thermostat is set to heating mode and the target temperature is set above the current room temperature. If the display is blank or unresponsive, check the wiring connections behind the wall plate.
Brivis Buffalo Light Flashing Codes (Red or Green)
If your Brivis Buffalo 20 has a red light flashing on the control board, it is communicating a fault code. This is one of the most searched Brivis issues in Melbourne, and for good reason. A flashing red light every 3 to 4 seconds typically indicates an ignition fault or lockout. On BX3 and BX5 models, a single green LED flashes in a repeating pattern every 4.8 seconds. Count the number of flashes in each cycle to identify the fault.
Older Buffalo 20 and Buffalo 85 models may use a red LED instead of green, but the flash code logic is the same.
Here is what each code means:
Slow single flash (steady rhythm): Normal operation, heater is idle and ready.
Slow double flash: Normal operation, thermostat is calling for heat.
1 flash (then long pause): Overheat condition. The supply air temperature has exceeded the safety limit. This is usually caused by restricted airflow from dirty filters, closed vents, or collapsed ductwork. The fan will run to cool the heat exchanger before the unit resets.
2 flashes: Pressure switch inactive. The combustion fan is running but the pressure switch has not closed, or the fan has stopped but the pressure switch is still closed. This can indicate a blocked flue, faulty pressure switch, or combustion fan issue.
3 flashes: Purge or interwait. The heater attempted to ignite but no flame was detected. This can happen after a long period of inactivity or if the gas supply was interrupted.
4 flashes: Pressure switch lockout. The pressure switch has failed to operate correctly after multiple attempts. This usually requires a technician to inspect the combustion fan assembly and pressure switch.
5 flashes: Ignition lockout. The heater tried to ignite multiple times and failed. The maximum number of re-ignition attempts has been reached. This is one of the most common fault codes Melbourne homeowners report. Causes include a dirty or worn spark igniter, faulty flame sensor, gas supply interruption, or a failed gas valve.
6 flashes: Valve fault lockout. The gas valve has been detected as disconnected, the relay contacts have failed to close, or there is a fault in the gas valve drive circuit. This code often points to a wiring or connection issue, though it can indicate a faulty gas valve.
7 flashes: Over-temperature lockout. The high-limit safety switch has tripped too many times in recent heating cycles. This is the escalated version of the 1-flash code. If the heater keeps overheating and resetting, it eventually locks out with this code. Restricted airflow is the most common cause, but a faulty fan motor or failed over-temperature switch can also trigger it.
8 flashes: Frequency lockout. A timing fault has been detected in the power supply or microprocessor clock. This can be caused by power supply issues or a failing control board.
9 flashes: Flame lockout (invalid flame). The flame sensor hardware has detected a fault during a safety check at startup.
10 flashes: False flame. The control board sensed flame when there should be none, usually during a startup safety check. This is a hardware fault.
11 flashes: SafeStart lockout. The startup safety checks did not complete in time. This can indicate a power supply issue, incorrect polarity at the power point, or a control board fault.
12 flashes: Secondary safeguard timing fault. An internal timing error on the control board.
3 slow flashes: Ground fault lockout. Flame variation has been detected due to a poor earth connection to the chassis ground.
What to Do When You See a Flash Code
The first step is always to try a reset. Turn the heater off at the isolating switch or power point, wait 30 seconds, and turn it back on. Many flash codes clear after a reset, particularly the 3-flash and 5-flash codes that can appear after the heater sits idle over summer.
If the same code returns after a reset, write it down and call a our licensed heating technicians at ExtrordinAir on 1800 296 885. Flash codes are designed to help your technician diagnose the problem faster.
The EPRL Error Light
Older Buffalo models (particularly the Buffalo 85 with TEK 321 or TEK 331 control boards) have a red LED labelled EPRL on the circuit board. This stands for Electronic Pilot Relighter.
When the EPRL light is flashing, it means the control board has detected a flame sensor fault. The flame sensor rod or pilot assembly is not detecting a stable flame.
In about 80% of cases, this is resolved by cleaning the flame sensor rod and air intakes. The flame sensor rod can be gently cleaned with fine steel wool or emery cloth until the metal is shiny. This is a standard part of a ducted heating service.
If cleaning the sensor does not resolve the fault, the control board itself may need replacing. Some older boards (like the TEK 331) have been discontinued, though reconditioned and compatible replacement boards may be available for your model.
When to Reset vs When to Call a Technician
A power reset is a safe and easy first step for most Brivis Buffalo faults. It clears temporary errors and restarts the ignition sequence.
A reset is worth trying when:
- Your heater has been sitting idle for weeks or months and will not start on the first cold day of the season.
- You have had a brief power outage or power surge.
- The heater ran normally yesterday but will not start today.
- You see a 3-flash or 5-flash code after the heater’s first startup attempt of the season.
Call a licensed technician when:
- The same error code returns after every reset.
- You can smell gas near the unit.
- The heater makes loud banging or popping noises during operation.
- You see a 6-flash, 7-flash, or 8-flash code.
- The heater is more than 15 years old and has never been serviced.
- You notice soot, discolouration, or a yellow (rather than blue) flame on the burners.
Gas heating repairs must be carried out by a licensed gasfitter in Melbourne. Working on gas appliances without the correct licence is both dangerous and illegal.
Keeping Your Buffalo Running Well
The best thing you can do for your Brivis Buffalo is book an annual service before winter. A qualified technician will clean the burners, check the flame sensor or thermocouple, inspect the heat exchanger for cracks, test the safety switches, and make sure the ductwork is in good shape.
Pre-season servicing catches small issues before they leave you without heating on a cold Melbourne morning. Most breakdowns may have been prevented with a routine annual check.
Sourcing Parts for Older Buffalo Models
Thermocouples, pilot assemblies, and gas valves for the Buffalo 85 and Buffalo 20 are still widely available through heating parts suppliers in Melbourne. These are standard service items that most technicians carry or can source quickly.
Control boards are where it gets trickier. Some older boards like the TEK 331 have been discontinued by Brivis. Reconditioned boards and compatible replacements are available through aftermarket suppliers, but stock is limited and availability can change. The TEK 321 board, which replaced the 331, is still available at the time of writing.
For Buffalo 120 models, parts availability is more limited again. These units date back to the late 1980s and early 1990s, and many components are no longer manufactured. If your Buffalo 120 needs a new control board or ignition module, your technician may recommend replacement over repair.
The good news is that replacement units are designed to sit on the same base box as the original Buffalo, which keeps installation costs down. Your existing ductwork can usually be reused as well, provided it is still in good condition. If it’s 30+ years old, you may need to consider heating duct replacement.